Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
BMC Oral Health ; 22(1): 449, 2022 10 19.
Artigo em Inglês | MEDLINE | ID: mdl-36261829

RESUMO

BACKGROUND: Peri-implantitis is a usual finding but estimates of its prevalence fluctuate very much. This may be due to the wide variety of disease definitions. This systematic review aims to estimate the overall prevalence of peri-implantitis and the effect of different study designs, function times and use of probing depth on prevalence rate. METHODS: Following electronic and manual searches of the literature published from January 2005 to December 2021, data were extracted from the studies fitting the study criteria. Fifty-seven articles were included in this study. RESULTS: Prevalence of peri-implantitis was 19.53% (95% CI 12.87-26.19) at the patient-level, and 12.53% (95% CI 11.67-13.39) at the implant-level and it remains highly variable even following restriction to the clinical case definition. The use of probing depth like diagnostic criteria affected the prevalence data. CONCLUSION: The results indicate that it remains essential the identification of the diagnostic markers for more accurate disease classification.


Assuntos
Implantes Dentários , Peri-Implantite , Humanos , Peri-Implantite/epidemiologia , Peri-Implantite/etiologia , Prevalência , Projetos de Pesquisa
2.
J Prosthodont Res ; 65(3): 291-297, 2021 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-33041277

RESUMO

Purpose To evaluate the influence of intraoral and extraoral digitization systems on marginal discrepancy of monolithic lithium disilicate and monolithic zirconia computer-aided design-computer-aided manufacturing (CAD-CAM) crowns.Methods Forty standardized machined stainless steel specimens with the characteristics of a first molar were manufactured and randomly assigned to two groups (n=20 each), depending on their material: monolithic lithium disilicate ceramic (LM), and monolithic zirconia (ZM). Then, each group was subdivided into two depending on the scanning system used: intraoral scanner (IOS), and extraoral scanner (EOS). The digitization process was standardized with two methacrylate devices, one for each scanner. After scanning and manufacturing of the crowns, the marginal discrepancy was measured under a scanning electron microscope (SEM). Data analysis was made using two-way analysis of variance (ANOVA) and the effect size with Cohen's d.Results All the measurements were within the limits considered acceptable. Regardless the restorative material significant differences between scanners were observed, being the effect from low to moderate. However, no differences were observed between the scanners in either the lithium disilicate or zirconia group.Conclusions The intraoral scan showed lower marginal discrepancy than the extraoral scan in CAD-CAM monolithic crowns, but these differences were not observed in each of the ceramic systems.


Assuntos
Adaptação Marginal Dentária , Planejamento de Prótese Dentária , Cerâmica , Desenho Assistido por Computador , Coroas , Materiais Dentários , Porcelana Dentária
3.
Materials (Basel) ; 13(21)2020 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-33143092

RESUMO

The precision of fit at the implant-abutment connection is an important criterion for the clinical success of restorations and implants. Several factors are involved among which are the abutment materials and manufacturing techniques. The aim of this study was to investigate the effect of two materials and methods of manufacturing implant abutments, milled titanium versus laser sintered Co-Cr, on the marginal misfit at the implant-abutment interface. Scanning electron microscopes (SEM) were used to geometrically measure the marginal vertical discrepancy of a total of 80 specimens, classified into eight categories, according to the implant system and abutment. The data were statistically analyzed by Student's paired t test, one-way and two-way ANOVA with the Bonferroni-Holm correction at the significance level of p = 0.05. Milled titanium abutments demonstrated the lowest misfit values in the implant systems analyzed. The marginal fit of all the groups was within the clinically acceptable range for implant prostheses.

4.
J Prosthodont ; 28(3): 299-304, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28152246

RESUMO

PURPOSE: Studies on the marginal fit of monolithic restorations are limited. This study aimed to evaluate the marginal fit among monolithic zirconia, monolithic lithium disilicate, and conventional metal-ceramic crowns and to compare the buccal and lingual surfaces. MATERIALS AND METHODS: Thirty standardized stainless steel master dies were fabricated (height: 5 mm; convergence: 6°; chamfer: 1 mm). The dies were randomly divided into three groups (n = 10 each) according to the material used to construct the crowns: group 1 (LM): Lava Plus; group 2 (DM): IPS e.max CAD; and group 3 (MC): Metal-ceramic. The crowns were luted in a standard manner onto the stainless steel master dies using conventional glass ionomer cement. The vertical marginal gap of the restorations was evaluated under a scanning electron microscope (SEM) at 500x magnification. One-way ANOVA, Tukey´s HSD test, and Student's paired t test were used to assess the marginal discrepancy among the groups. The cutoff value for statistical significance was set at α = 0.05. RESULTS: Significant differences among the three groups (p = 0.0001) were recorded. DM group showed the lowest discrepancies (27.95 ± 9.37 µm). Significant differences were observed for the buccal (p = 0.007) and lingual (p = 0.0001) surfaces between the DM group and the other groups. CONCLUSIONS: The accuracy of fit achieved for the three groups was within the range of clinical acceptance. IPS e.max CAD showed the lowest discrepancies.


Assuntos
Adaptação Marginal Dentária , Planejamento de Prótese Dentária , Cerâmica , Desenho Assistido por Computador , Coroas , Porcelana Dentária , Humanos
5.
J Prosthodont ; 28(7): 750-756, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30039897

RESUMO

PURPOSE: To compare the survival, success rates, and biological/technical complications of posterior metal-ceramic (MC) and zirconia fixed partial dentures (FPDs). MATERIALS AND METHODS: A total of 40 patients requiring 40 posterior FPDs were randomly assigned to receive 20 zirconia and 20 MC restorations. The restorations were examined 1 week (baseline) and 1, 3, and 5 years after the end of treatment. Technical and biological outcomes were compared. Data were statistically analyzed using the Wilcoxon signed-rank and Mann-Whitney U tests. RESULTS: The survival rates of both groups were 100%, and the success rates were 80% (zirconia) and 100% (MC). No biological complications were observed. Minor chipping was found in 20% of the zirconia restorations. No differences in periodontal parameters were observed between groups. CONCLUSIONS: Zirconia FPDs exhibited the same survival rate (100%) as MC FPDs after 5 years; however, the success rate was 80%, because an increased rate of chipping was observed in zirconia restorations.


Assuntos
Planejamento de Dentadura , Prótese Parcial Fixa , Cerâmica , Porcelana Dentária , Falha de Restauração Dentária , Seguimentos , Humanos , Zircônio
6.
Dent Mater J ; 36(4): 387-393, 2017 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-28367911

RESUMO

The purpose of this study is to evaluate the precision of fit of posterior crowns made from three commercial CAD/CAM zirconia ceramics and conventional metal-ceramic technique. The external and internal marginal fit of the crowns was evaluated using direct SEM-based measurements. The data were subjected to Kruskal-Wallis, multicomparison post hoc analysis and Wilcoxon rank sum tests (α=0.05). Significant differences were observed for the external (p<0.002) and the internal (p<0.0001) marginal evaluation among the groups. No differences were observed between the buccal and lingual surfaces for the external (p=0.34) and internal (p=0.55) evaluations. No differences were showed between the external and internal measurements (p=0.37). The accuracy of fit was within the range of clinical acceptance. The lowest discrepancies corresponded to the NobelProcera group for external (39.3±11.81 µm) and internal (41.09±7.54 µm) marginal fit. The results confirmed that destructive methods are not required to assess the marginal fit of dental prosthetic crowns.


Assuntos
Coroas , Planejamento de Prótese Dentária , Cerâmica , Desenho Assistido por Computador , Adaptação Marginal Dentária , Porcelana Dentária , Humanos
7.
J Dent ; 49: 22-32, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27134045

RESUMO

OBJECTIVES: To validate a new index for assessing the whole concept of oral health-related quality of life (OHRQoL) of implant-prosthesis wearers. METHODS: 113 patients who were not requesting dental treatment were assigned to: Group 1 (CD; n=38): complete denture users (control); Group 2 (IO; n=38): implant overdenture wearers; and Group 3 (HP; n=37): hybrid implant prosthesis users. Patients answered the newly-designed 'Quality of Life related to Function, Aesthetics, Socialization, and Thoughts about health-behavioural habits' (QoLFAST-10) and the Oral Health Impact Profile (OHIP-20sp) questionnaires. Information on global oral satisfaction, socio-demographic, clinical, and prosthetic-related data were gathered. The QoLFAST-10 was investigated for reliability and validity. The Spearman's test determined the correlations between both indices' scores. Descriptive and non-parametric probes were run to assess the influence of the study variables on the OHRQoL (α=0.05). RESULTS: The QoLFAST-10 confirmed its psychometric capacity. HP wearers reported significantly better global and functional satisfaction than did IO wearers. The latter revealed significantly less consciousness about the importance of health-behavioural habits than did CD and HP groups. The level of education, complaints about the mouth, and the global oral satisfaction measures significantly modulated the QoLFAST-10 scores. CONCLUSIONS: Implant overdentures supplied lower functional and global satisfaction than did hybrid prostheses, and represent the least predictable option concerning the maintenance of the restoration. CLINICAL SIGNIFICANCE: The QoLFAST-10 may help in estimating the impact of implant restorations on patients' well-being. In this regard, hybrid prostheses seem to be the implant treatment of choice when compared with overdentures.


Assuntos
Revestimento de Dentadura , Prótese Dentária Fixada por Implante , Humanos , Saúde Bucal , Satisfação do Paciente , Qualidade de Vida , Reprodutibilidade dos Testes
8.
Int J Prosthodont ; 29(3): 256-8, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27148985

RESUMO

PURPOSE: The aim of this study was to investigate and compare the marginal fit of posterior fixed dental prostheses (FDPs) made of monolithic and veneered computer-aided design/computer-assisted manufacture (CAD/CAM) zirconia ceramic with metal-ceramic posterior FDPs. MATERIALS AND METHODS: Thirty standardized steel dies were prepared to receive posterior three-unit FDPs. Specimens were randomly divided into three groups (n = 10): (1) metal-ceramic (control group), (2) veneered zirconia, and (3) monolithic zirconia. All FDPs were cemented using a glass-ionomer cement. The specimens were subjected to thermal cycling (5°C to 55°C). A scanning electron microscope (SEM) with a magnification of ×500 was used for measurements. The data were statistically analyzed using one-way analysis of variance and paired t test. RESULTS: Both zirconia groups showed similar vertical marginal discrepancies, and no significant differences (P = .661) in marginal adaptation were observed among the groups. No differences were observed in either group in marginal discrepancies between surfaces or abutments. CONCLUSION: Monolithic zirconia posterior FDPs exhibit similar vertical marginal discrepancies to veneered zirconia posterior FDPs. No influence of localization measurements was observed.


Assuntos
Cerâmica/química , Adaptação Marginal Dentária , Materiais Dentários/química , Facetas Dentárias , Prótese Parcial Fixa , Ligas Metalo-Cerâmicas/química , Zircônio/química , Cimentação/métodos , Desenho Assistido por Computador , Dente Suporte , Planejamento de Dentadura , Cimentos de Ionômeros de Vidro/química , Humanos , Microscopia Eletrônica de Varredura , Distribuição Aleatória , Propriedades de Superfície , Ítrio/química
9.
J Prosthodont ; 25(7): 550-556, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26380955

RESUMO

PURPOSE: To evaluate the fracture load of 3-unit zirconia-based posterior fixed dental prostheses (FDPs) before and after veneering the frameworks. MATERIALS AND METHODS: Forty standardized stainless-steel master dies were fabricated (height: 5 mm, convergence: 6º, chamfer: 1 mm) and randomly screwed in pairs onto metal bases. The bases were randomly divided into two groups (n = 20 each) according to the zirconia CAD/CAM system used for constructing 3-unit structures for FDPs: group 1 (L): Lava All-ceramic, group 2 (Z): IPS e.max ZirCAD. Half of the zirconia structures per group were randomly selected and veneered, while the remaining half was left unveneered. The specimens were luted in standard fashion onto the stainless steel master dies using conventional glass ionomer cement. All specimens were tested for fracture load (FL). Specimens were subjected to a three-point bending test until fracture by applying an axial compressive load at the central fossa of the pontics with a universal testing machine at a 0.5 mm/min crosshead speed. Wilcoxon's rank-sum test and Weibull statistics were used for statistical analysis (α = 0.05). RESULTS: L structures recorded significantly higher values of load to fracture than the Z group both before and after veneering. Within each ceramic group, no differences were found between unveneered and veneered frameworks. CONCLUSIONS: Although further studies are necessary to corroborate these findings, both zirconia systems could be recommended for restoring posterior teeth on the basis of the fracture load values recorded in this experiment (>1000 N). The veneering procedure did not affect the overall load to fracture in any group.


Assuntos
Desenho Assistido por Computador , Porcelana Dentária , Facetas Dentárias , Zircônio , Falha de Restauração Dentária , Análise do Estresse Dentário , Humanos , Teste de Materiais , Distribuição Aleatória
10.
Int J Prosthodont ; 28(5): 509-11, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26340011

RESUMO

PURPOSE: The aim of this study was to analyze the marginal and internal fit of metalceramic and zirconia-based crowns. MATERIALS AND METHODS: Forty standardized steel specimens were prepared to receive posterior crowns and randomly divided into four groups (n = 10): (1) metal-ceramic, (2) NobelProcera Zirconia, (3) Lava Zirconia, and (4) VITA In-Ceram YZ. All crowns were cemented with glass-ionomer agent and sectioned buccolingually. A scanning electron microscope was used for measurements. Kruskal-Wallis and Wilcoxon signed rank test (α = .05) statistical analyses were conducted. RESULTS: Significant differences (P < .0001) in marginal discrepancies were observed between metal-ceramic and zirconia groups. No differences were found for the axial wall fit (P = .057). Significant differences were shown among the groups in discrepancies at the occlusal cusp (P = .0012) and at the fossa (P = .0062). No differences were observed between surfaces. CONCLUSIONS: All zirconia groups showed better values of marginal discrepancies than the metal-ceramic group. Procera Zirconia showed the lowest gaps.


Assuntos
Desenho Assistido por Computador , Coroas , Adaptação Marginal Dentária , Materiais Dentários/química , Planejamento de Prótese Dentária , Ligas Metalo-Cerâmicas/química , Zircônio/química , Cimentação/métodos , Porcelana Dentária/química , Cimentos de Ionômeros de Vidro/química , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Distribuição Aleatória , Propriedades de Superfície
11.
J Clin Exp Dent ; 7(2): e250-3, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26155341

RESUMO

BACKGROUND: In recent years there has been an improvement of zirconia ceramic materials to replace posterior missing teeth. To date little in vitro studies has been carried out on the fracture resistance of zirconia veneered posterior fixed dental prostheses. This study investigated the fracture resistance and the failure mode of 3-unit zirconia-based posterior fixed dental prostheses fabricated with two CAD/CAM systems. MATERIAL AND METHODS: Twenty posterior fixed dental prostheses were studied. Samples were randomly divided into two groups (n=10 each) according to the zirconia ceramic analyzed: Lava and Procera. Specimens were loaded until fracture under static load. Data were analyzed using Wilcoxon´s rank sum test and Wilcoxon´s signed-rank test (P<0.05). RESULTS: Partial fracture of the veneering porcelain occurred in 100% of the samples. Within each group, significant differences were shown between the veneering and the framework fracture resistance (P=0.002). The failure occurred in the connector cervical area in 80% of the cases. CONCLUSIONS: All fracture load values of the zirconia frameworks could be considered clinically acceptable. The connector area is the weak point of the restorations. Key words:Fixed dental prostheses, zirconium-dioxide, zirconia, fracture resistance, failure mode.

12.
J Prosthet Dent ; 102(6): 378-84, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19961996

RESUMO

STATEMENT OF PROBLEM: Marginal discrepancies of zirconia posterior fixed dental prostheses (FDPs) fabricated using various systems have been assessed to determine the quality of the restorations and facilitate clinical use; however, studies are limited and results are ambiguous because of the sample sizes and measurement methods. PURPOSE: The purpose of this in vitro study was to compare changes in marginal fit of posterior fixed dental prostheses of 3 zirconia systems manufactured using CAD/CAM technology and metal ceramic posterior fixed dental protheses fabricated with the conventional lost-wax technique, before and after cementation. MATERIAL AND METHODS: Forty standardized master steel dies with 2 abutments simulating first mandibular premolars were fabricated to receive a posterior 3-unit FDP (from first molar to first premolar) and divided into 4 groups (n=10): Lava All-Ceramic System, Procera Bridge Zirconia, VITA In-Ceram 2000 YZ, and metal ceramic (control group). All FDPs were prepared for an internal space of 50 microm. The external marginal gap of the restorations was investigated by measuring 30 points in the middle of the buccal and lingual surfaces; therefore, 60 measurements per abutment were recorded. Measurements were made with an image analysis program on the master steel model before and after conventional cementation with a glass ionomer agent (Ketac Cem Easymix). The data obtained were statistically analyzed using 1-way ANOVA, Duncan's multiple range post hoc test, and Student's paired t test (alpha=.05). RESULTS: No significant differences in the vertical marginal fit before and after cementation were recorded for the analyzed groups. The marginal discrepancy of Procera abutments before and after cementation (9 +/-10 microm and 12 +/-9 microm, respectively) was less than that of the other groups. Significant differences (P=.001) were observed in marginal adaptation between Procera Bridge Zirconia and the other groups. CONCLUSIONS: The results of this study showed that cementation did not cause a significant increase in the vertical marginal discrepancies of the FDPs and that an internal space of 50 mum provided a high precision of fit of the restorations. The accuracy of fit achieved for the 3 zirconium oxide groups analyzed was within the range of clinical acceptance, and the discrepancies were lower than in the metal ceramic group. Procera Bridge Zirconia showed the lowest vertical discrepancies.


Assuntos
Adaptação Marginal Dentária , Prótese Parcial Fixa , Dente Pré-Molar , Cimentação , Desenho Assistido por Computador , Técnica de Fundição Odontológica , Porcelana Dentária , Planejamento de Prótese Dentária , Humanos , Teste de Materiais , Ligas Metalo-Cerâmicas , Dente Molar , Zircônio
13.
Int J Prosthodont ; 22(4): 374-7, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19639075

RESUMO

The purpose of this study was to compare two measurement methods for the external marginal fit of zirconia posterior fixed partial dentures (FPDs) fabricated using computer-aided design/manufacturing technology and metal-ceramic posterior FPDs fabricated using the conventional lost-wax technique. The null hypothesis was that there would be no differences between the measurement methods. Forty standardized steel specimens were prepared to receive posterior three-unit FPDs. Specimens were divided into four groups (n = 10): (1) metal-ceramic, (2) Procera Bridge Zirconia, (3) Lava AllCeramic System, and (4) Vita In-Ceram YZ 2000. All FPDs were luted with glass-ionomer cement (Ketac Cem EasyMix, 3M ESPE). Two measurement methods were used to analyze marginal fit: an image analysis (IA) program and a scanning electron microscope (SEM) (JEOL JSM-6400) with magnifications of 340 and 31,000, respectively. Marginal fit was measured at the same point on each abutment. Significant interaction was observed between measurement method and material (P = .0019). Therefore, the measurement method is not independent of the restoration material. Differences among groups were observed for IA (P = .0001) and SEM (P = .0013). Significant differences were observed for the Procera (P = .0050) and metal-ceramic (P = .0039) specimen groups when both measurement methods were evaluated separately. Accuracy of fit achieved by the four groups analyzed was within the range of clinical acceptance, yielding Procera Bridge Zirconia to have the best marginal fit using both measurement methods.


Assuntos
Porcelana Dentária/química , Planejamento de Dentadura , Prótese Parcial Fixa , Ligas Metalo-Cerâmicas/química , Zircônio/química , Cimentação/métodos , Desenho Assistido por Computador , Dente Suporte , Técnica de Fundição Odontológica , Materiais Dentários/química , Cimentos de Ionômeros de Vidro/química , Humanos , Processamento de Imagem Assistida por Computador , Óxido de Magnésio/química , Teste de Materiais , Microscopia Eletrônica de Varredura , Cimento de Policarboxilato/química , Propriedades de Superfície , Tecnologia Odontológica , Óxido de Zinco/química
14.
Int J Prosthodont ; 21(5): 398-9, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18950059

RESUMO

The aim of this study was to investigate the marginal fit of posterior fixed partial dentures (FPDs) made with 2 computer-aided design/computer-assisted manufacture systems--Procera Bridge Zirconia (Nobel Biocare) and Lava AllCeramic System (3M ESPE)--and to analyze the differences between abutments and between buccal and lingual surfaces. Twenty standardized specimens were prepared to receive posterior 3-unit FPDs. FPDs were fabricated according to the manufacturer's instructions. A scanning microscope (JSM-6400, JEOL) with a magnification of 1,000x was used for measurements. Three-way analysis of variance showed significant differences (P < .001) in marginal adaptation between the ceramic groups. Procera Bridge Zirconia showed the lowest discrepancies (26 +/- 19 microm). No significant differences were observed between abutments and surfaces, and no significant interaction was observed among the ceramic system, abutments, and surfaces. The accuracy of fit achieved by both zirconia systems was within the range of clinical acceptability, with Procera Bridge Zirconia showing the best marginal fit.


Assuntos
Desenho Assistido por Computador/instrumentação , Dente Suporte , Planejamento de Dentadura/instrumentação , Prótese Parcial Fixa , Análise de Variância , Cerâmica , Humanos , Ajuste de Prótese/instrumentação , Zircônio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...